NH
3
的检测具有广泛的应用
采用光声法检测NH
3
是当前研究的热点
而确定NH
3
的吸收谱线则是实现光声法检测NH
3
的前提。采用外腔可调谐半导体激光器构造了光声气体检测系统
检测了NH
3
的近红外吸收谱线
获得了常温常压下NH
3
在1 515~1 532 nm范围内的吸收光谱。实验确认了NH
3
在1 515.2
1 516.0
1 518.0
1 519.9
1 522.4
1 527.0
1 531.7 nm处存在强吸收。HITRAN 2004光谱数据库在近红外1.5 μm波段NH
3
的吸收谱线数据未见报道
该结果为研究光声法检测NH
3
提供了更多可选择的吸收谱线。
Ammonia detecting has a wide range of applications
and currently attracts considerable attention through the photoacoustic. The premise of detecting is to determine the absorption lines of ammonia. At normal pressure and temperature
the absorption spectrum of ammonia at the range of 1 515~1 532 nm was measured with an external cavity tunable semiconductor laser through the photoacoustic spectroscopy gas detection theory. Seven ammonia absorption lines
at 1 515.2
1 516.0
1 518.0
1 519.9
1 522.4
1 527.0
1 531.7 nm
were scanned by resetting the laser tuning range and were confirmed having strength absorption. The spectroscopic database of HITRAN 2004 do not contain ammonia spectrum in the 1.5 μm region
and the results of this paper provided more ammonia absorption lines to choose for the ammonia detection research based on photoacoustic.
光声光谱外腔可调谐半导体激光器吸收谱线NH3检测
photoacoustic spectroscopyexternal cavity tunable semiconductor laserabsorption lineammonia detection
Zheng J X, Guan Y C, Ran H L. Application and research progress of ammonia sensor [J]. New Chemical Materials (化工新型材料), 2010, 38(2):6-8,22 (in Chinese).
Justo D, Mashav N, Arbel Y, et al. Increased erythrocyte aggregation in men with coronary artery disease and erectile dysfunction [J]. International Journal of Impotence Research, 2009, 21(3):192-197.
Larsen M H, Hviid T V F. Human leukocyte antigen-G polymorphism in relation to expression, function, and disease [J]. Human Immunology, 2009, 70(12):1026-1034.
Peng Y. Tunable Fiber Laser Based Photoacoustic Spectroscopy Technology for Trace Gas Detection . Dalian: Dalian University of Technology, 2011(in Chinese).
Wang J W, Zhang W, Liang L R, et al. Tunable fiber laser based photoacoustic spectrometer for multi-gas analysis [J]. Sensors and Actuators B, 2011, 160:1268-1272.
Wang Q Y, Wang J W, Li L, et al. An all-optical photoacoustic spectrometer for trace gas detection [J]. Sensors and Actuators B, 2011, 153:214-218.
Wang J, Zhang W, Li L, et al. Breath ammonia detection based on tunable fiber laser photoacoustic spectroscopy [J]. Appl. Phys. B, 2011, 103:263-269.
Cao P, Bai Y, Zhao D X, et al. Structural and ferromagnetism properties of NH3 plasma post-treated Co-doped ZnO thin film [J]. Chin. J. Lumin.(发光学报), 2011, 32(4):383-386 (in Chinese).
Mroziewicz B. External cavity wavelength tunable semiconductor laser—a review [J]. Opto-Electronics Review, 2008, 16(4):347-366.
Rothmana L S, Jacquemarta D, Barbeb A, et al. The HITRAN 2004 molecular spectroscopic database [J]. Journal of Quantitative Spectroscopy & Radiative Transfer, 2005, 96(2):139-204.
Lins B, Pflaum F, Engelbrecht R, et al. Absorption line strengths of 15NH3 in the near infrared spectral region [J]. Applied Physics B, 2011, 102:293-301.
Webber M E. Diode Laser Measurements of NH3 and CO2 for Combustion and Bioreactor Applications . Stanford: Stanford University, 2001.
Webber M E, Baer D S, Hanson R K. Ammonia monitoring near 1.5 μm with diode-laser absorption sensors [J]. Applied Optics, 2001, 40(12):2031-2042.
Peeters R, Berden G, Apituley A, et al. Open-path trace gas detection of ammonia based on cavity-enhanced absorption spectroscopy [J]. Applied Physics B, 2000, 71:231-236.
Claps R, Englich F V, Leleux D P, et al. Ammonia detection by use of near-infrared diode-laser-based overtone spectroscopy [J]. Applied Optics, 2001, 40(24):4387-4394.
0
浏览量
38
下载量
1
CSCD
关联资源
相关文章
相关作者
相关机构