刘保生, 闫潇娜, 种宝红, 曹世娜, 吕运开. 利用铕(Ⅲ)-诺氟沙星-十二烷基硫酸钠的 光致发光及稀土敏化荧光法测定硫酸新霉素的浓度[J]. 发光学报, 2012,33(4): 453-457
LIU Bao-sheng, YAN Xiao-na, CHONG Bao-hong, CAO Shi-na, LV Yun-kai. Determination of Trace Neomycin Sulfate by Photoluminescence and Lanthanide Sensitized Fluorescence Quenching on Europium-norfloxacin-SDS[J]. Chinese Journal of Luminescence, 2012,33(4): 453-457
刘保生, 闫潇娜, 种宝红, 曹世娜, 吕运开. 利用铕(Ⅲ)-诺氟沙星-十二烷基硫酸钠的 光致发光及稀土敏化荧光法测定硫酸新霉素的浓度[J]. 发光学报, 2012,33(4): 453-457 DOI: 10.3788/fgxb20123304.0453.
LIU Bao-sheng, YAN Xiao-na, CHONG Bao-hong, CAO Shi-na, LV Yun-kai. Determination of Trace Neomycin Sulfate by Photoluminescence and Lanthanide Sensitized Fluorescence Quenching on Europium-norfloxacin-SDS[J]. Chinese Journal of Luminescence, 2012,33(4): 453-457 DOI: 10.3788/fgxb20123304.0453.
室温下
在pH=7.4的氨-氯化铵缓冲溶液中
铕(Ⅲ)与诺氟沙星反应形成稳定络合物
产生稀土敏化荧光
其最佳激发、发射波长分别为
ex
=340 nm、
em
=612 nm
表面活性剂十二烷基硫酸钠(SDS)的加入使其荧光强度进一步增加。在该反应体系中加入适量硫酸新霉素溶液
铕(Ⅲ)与诺氟沙星络合物的激发、发射峰位置不变
但荧光强度降低
据此建立了灵敏的测定硫酸新霉素的荧光分析方法。硫酸新霉素的浓度在0.909~22.72 mg/L范围内符合线性关系。该方法的检出限为0.40 mg/L
可用于片剂及滴眼液中硫酸新霉素含量的测定
快速、简便、结果满意。6次平行测定的回收率为90.5%~102.3%
相对标准偏差为1.4%~3.5%。
In the ammonia-ammonium chloride buffer solution of pH=7.4
europiumion(Eu
3+
) and norfloxacin(NFLX) react and combine as steady complex under room temperature. The complex shows its sensitized fluorescence of rare earth. The maximum excitation wavelength and maximum emission wavelength are 340 nm and 612 nm
respectively. The fluorescence intensity has a further increase in sodium dodecyl sulfate(SDS). When neomycin sulfate solution is added
the fluorescence intensity of the system of Eu
3+
-NFLX-SDS diminishes
while the locations of the excitation and emission wavelengths stay the same. According to this result
a new way to determine the concentration of neomycin sulfate is established. The concentration range that neomycin sulfate can detect is 0.909~22.7 mg/L. The detection limit is up to 0.4 mg/L. This measurement has been applied to determine neomycin sulfate in tablet and drops. The relative standard deviation is 1.4%~3.5% for 6 parallel determination of neomycin sulfate samples and the recovery is 90.5%~102.3%.
硫酸新霉素铕诺氟沙星十二烷基硫酸钠荧光猝灭
neomycin sulfateeuropiumionnorfloxacinsodium dodecyl sulfatefluorescence quenching
Deng Jiuyao, Huang Wenxin, Jiang Zhiliang. Resonance scattering spectral analysis of trace neotamicin [J]. Anal. Test. Technol. Instrum.(分析测试技术与仪器), 2007, 13(3):174-176 (in Chinese).[2] Lu Fang, Liu Qun, Yu Xianghua, et al. Assay of neomycin sulfate by polarimetry [J]. Chin. J. Veterinary Drug.(中国兽药杂志), 2006, 40(6):31-32 (in Chinese).[3] Huang Yun, Xu Xingya. Preparation and quality control of neomycin sulfate and hydrocortisone gel [J]. Practi. Pharm. Clin. Rem.(实用药物与临床), 2010, 13(6):428-430 (in Chinese).[4] ?an?ek Majheni?A, Rogelj I, Perko B. Enterococci from tolminc cheese: population structure, antibiotic susceptibility and incidence of virulence determinants [J]. Int. J. Food Microbiol., 2005, 102(2):239-244.[5] Molina M P, Althaus R L, Molina A, et al. Antimicrobial agent detection in ewes milk by the microbial inhibitor test brilliant black reduction test : BRT AiM [J]. Int. Dairy J. A, 2003, 13(10):821-826.[6] Jiang Xia, Chen Yi. Qualitative analysis of compound neomycin nasal drops by TLC [J]. Drug Standards of China (中国药品标准), 2003, 4(5):63-64 (in Chinese).[7] Clarot I, Regazzeti A, Auzeil N, et al. Analysis of neomycin sulfate and framycetin sulfate by high-perfrmance liquid chromatography using evaporative light scattering detection [J]. J. Chromatogr. A, 2005, 1087(1-2):236-244.[8] Megoulas N C, Koupparis M A. Enhancement of evaporative light scattering detection in high-performance liquid chromatographic determination of neomycin based on highly volatile mobile phase, high- molecular-mass ion-pairing reagents and controlled peak shape [J]. J. Chromatogr. A, 2004, 1057(1-2):125-131.[9] Vuci?evi?-Prceti?K, Cservenk R, Radulovi?N. Determination of neomycin and oxytetracycline in the presence of their impurities in veterinary dosage forms by high-performance liquid chromatography/tandem mass spectrometry [J]. J. AOAC Int., 2011, 94(3):750-757.[10] Jiang Hong, Liu Yan. Spectrophotometric determination of kanamycin and neomycin by ionassociation reaction with the binary complex of La(Ⅲ) and methyl blue [J]. Phys. Test. Chem. Anal. Part B: Chem. Anal.(理化检验:化学分册), 2007, 43(1):54-56 (in Chinese).[11] Amin A S, Issa Y M. Ion-association method for the colorimetric determination of neomycin sulphate in pure and dosage forms [J]. Spectrochim. Acta A: Mol. Biomol. Spectrosc., 2003, 59(4):663-670.[12] Lu Fang, Liu Qun, Yu Xianghua. Determination of neomycin sulfate in feed by polarimetry [J]. China Feed (中国饲料), 2006(18):31-32 (in Chinese).[13] Jin Y, Jang J W, Lee M H, et al. Development of ELISA and immunochromatographic assay for the detection of neomycin [J]. Clin. Chim. Acta, 2006, 364(1-2):260-266.[14] Wang S, Xu B, Zhang Y, et al. Development of enzyme-linked immunosorbent assay(ELISA) for the detection of neomycin residues in pig muscle, chicken muscle, egg, fish, milk and kidney [J]. Meat Sci., 2009, 82(1):53-58[15] Sun Chunyan, Ping Hong, Li Hongkun, et al. The fluorescence characteristic of yttrium(Ⅲ) ciprofloxacin complex and its application [J]. Chin. J. Lumin.(发光学报), 2010, 31(5):646-650 (in Chinese).[16] Palvannan T, Boopathy R. Interaction of aminoglycoside antibiotics with surface Asp and Glu residues of phosphatidylinositol-specific phospholipase C [J]. Enzyme Microb. Technol., 2006, 38(7):899-904.[17] Zhang Qin, Huang Guancun, Zhao Ling, et al. Influence of pH and ions on sorption of norfloxacin on humic acid [J]. China Environ. Sci.(中国环境科学), 2011, 31(1):78-83 (in Chinese).[18] Liu Baosheng, Xue Chunli, Wang Jing, et al. Studies on the interaction between ciprofloxacin and ofloxacin in presence of bovine serum albumin by spectroscopic methods [J]. Chin. J. Lumin.(发光学报), 2010, 31(2):285-290 (in Chinese).