王玉田, 赵煦, 潘钊等. 基于荧光光谱的五维数据处理方法[J]. 发光学报, 2016,37(11): 1436-1443
WANG Yu-tian, ZHAO Xu, PAN Zhao etc. Processing Method of Five-dimensional Data Based on Fluorescence Spectra[J]. Chinese Journal of Luminescence, 2016,37(11): 1436-1443
王玉田, 赵煦, 潘钊等. 基于荧光光谱的五维数据处理方法[J]. 发光学报, 2016,37(11): 1436-1443 DOI: 10.3788/fgxb20163711.1436.
WANG Yu-tian, ZHAO Xu, PAN Zhao etc. Processing Method of Five-dimensional Data Based on Fluorescence Spectra[J]. Chinese Journal of Luminescence, 2016,37(11): 1436-1443 DOI: 10.3788/fgxb20163711.1436.
石油是一种成分复杂的混合物,通过常规的检测方法很难对其进行定性识别。本文用汽、煤、柴油的混合物来模拟环境中的油类污染物。汽、煤、柴油在特定波长范围的激发下可以发出含有物质自身信息的荧光,根据朗伯-比尔定律可知荧光强度与物质浓度成正比,利用该性质对特定物质进行识别。通过FS920稳态荧光光谱仪对样本进行测量,将实验所得的三维数据拓展为五维数据,提出了一种将展开偏最小二乘耦合到残差四线性的五维数据处理方法,同时采用五维平行因子法和该算法分解数据,实现了对汽、煤油的定量分析,并恢复出了其激发和发射光谱。结果表明,展开偏最小二乘法的分析效果更好。
As a complex mixture of components
petroleum is difficult to be qualitatively identified by conventional detection methods. In this paper
the mixture of gasoline
kerosene and diesel was used to simulate the oil pollutants in the environment. The gasoline
kerosene and diesel could emit fluorescence with the material self information under the excitation of the specific wavelength range
and the fluorescence intensity was directly proportional to the concentration of the substance from the Lambert-Beer law
which was used to identify the kind of the oil. These samples were measured by FS920 steady state fluorescence spectrometer. The data were added to five-dimensional array data by Savitzky-Golay method
then the fourth-order date that contained complex information is obtained to analyze applications. A fourth-order correction method
which coupled unfolded partial least-squares to residual quadrilinearization
was proposed to deal with the five-way data. In order to test its predictive ability
the parallel factor method was used as a reference. Both of them can retrieve the excitation and emission profiles from the test samples. However
the REP value shows that the new method has higher precision than parallel factor analysis.
定性识别五维数据展开偏最小二乘法平行因子法
qualitative identificationfive-way dataunfolded partial least squares methodparallel factor method
CHAO K, WU H L, YU Y J, et al.. An alternative quadrilinear decomposition algorithm for four-way calibration with application to analysis of four-way fluorescence excitation-emission-pH data array [J]. Anal. Chim. Acta, 2013, 758(1):45-57.
GOICOECHEA H C, CALIMAG-WILLIAMS K, CAMPIGLIA A D. Multi-way partial least-squares and residual bi-linearization for the direct determination of monohydroxy-polycyclic aromatic hydrocarbons on octadecyl membranes via room-temperature fluorescence excitation emission matrices [J]. Anal. Chim. Acta, 2012, 717(5):100-109.
CALIMAG-WILLIAMS K, KNOBEL G, GOICOECHEA H C, et al.. Achieving second order advantage with multi-way partial least squares and residual bi-linearization with total synchronous fluorescence data of monohydroxy-polycyclic aromatic hydrocarbons in urine samples [J]. Anal. Chim. Acta, 2014, 811:60-69.
YANG R, LIU R, XU K. Detection of adulterated milk using two-dimensional correlation spectroscopy combined with multi-way partial least squares [J]. Food Biosci., 2013, 2:61-67.
SHAHLAEI M, FASSIHI A, SAGHAIE L, et al.. Prediction of partition coefficient of some 3-hydroxy pyridine-4-one derivatives using combined partial least square regression and genetic algorithm [J]. Res. Pharmaceut. Sci., 2014, 9(2):143-153.
HANAFI M, OUERTANI S S, BOCCARD J, et al.. Multi-way PLS regression: monotony convergence of tri-linear PLS2 and optimality of parameters [J]. Computat. Stat. Data Anal., 2015, 83:129-139.
OLIVIERI A C. Analytical advantages of multivariate data processing. One, two, three, infinity? [J]. Adv. Nurs. Sci., 2008, 80(15):5713-5720.
BRO R, ANDERSEN C M. Theory of net analyte signal vectors in inverse regression [J]. J. Chemomet., 2003, 17(12):646-652.
OLIVIERI A C, ARANCIBIA J A, PEA A M D L, et al.. Second-order advantage achieved with four-way fluorescence excitation-emission-kinetic data processed by parallel factor analysis and trilinear least-squares. Determination of methotrexate and leucovorin in human urine [J]. Anal. Chem., 2004, 76(19):5657-5666.
ARANCIBIA J A, OLIVIERI A C, GIL D B, et al.. Trilinear least-squares and unfolded-PLS coupled to residual trilinearization: new chemometric tools for the analysis of four-way instrumental data [J]. Chemomet. Intel. Lab. Syst., 2006, 80(1):77-86.
LEURGANS S, ROSS R T. Multilinear models: applications in spectroscopy [J]. Stat. Sci., 1992, 7(3):289-310.
BRO R. PARAFAC. Tutorial and applications [J]. Chemomet. Intel. Lab. Syst., 1997, 38(2):149-171.
PEA A M D L, MERS I D, GIRN A J, et al.. Evaluation of unfolded-partial least-squares coupled to residual trilinearization for four-way calibration of folic acid and methotrexate in human serum samples [J]. Talanta, 2007, 72(4):1261-1268.
杜树新,杜阳锋,武晓莉. 基于三维荧光导数光谱的水体有机污染物浓度检测 [J]. 光谱学与光谱分析, 2010, 30(12):3268-3271.DU S X, DU Y F, WU X L. Detection of dissolved organic matter based on three-dimensional first-order derivative fluorescence spectrometry [J].Spect. Spect. Anal., 2010, 30(12):3268-3271.(in Chinese)
0
浏览量
40
下载量
1
CSCD
关联资源
相关文章
相关作者
相关机构