浏览全部资源
扫码关注微信
1. 中国科学院长春光学精密机械与物理研究所, 激发态物理重点实验室
2. 东北师范大学化学学院, 多酸化学研究所
3. 白城广播电视大学
收稿:2006-10-14,
修回:2007-1-16,
纸质出版:2007-05-20
移动端阅览
岳淑美, 张莉, 李斌, 刘畅, 李文连. 钌(Ⅱ)配合物有机改性干凝胶的氧传感性能[J]. 发光学报, 2007,28(3): 345-348
YUE Shu-mei, ZHANG Li, LI Bin, LIU Chang, LI Wen-lian. Oxygen Sensing Properties Based on Organically Modified Sol-gel Doped with Ru-Dppz[J]. Chinese Journal of Luminescence, 2007,28(3): 345-348
采用溶胶-凝胶法以正硅酸乙酯(TEOS)和正辛基三乙氧基硅烷(Octyl-triEOS)为共先驱体制备了掺杂二氯化二联吡啶(二吡啶并[3
2-a 2
3-c]吩嗪)合钌(Ru-Dppz)的干凝胶.考察了Ru-Dppz在乙醇溶液和干凝胶内的荧光行为
发现在干凝胶中配合物的发射光谱较乙醇溶液中有明显蓝移.与固态本体配合物相比
干凝胶内Ru-Dppz的荧光寿命有明显增加.以Ru-Dppz为荧光指示剂的有机改性氧传感材料具有灵敏度高、响应时间短及稳定性好等优点.该复合材料中有机改性剂的加入提高了氧的通透性
降低了发光分子间的浓度自猝灭进而改善了材料传感的灵敏度.
Tang Y,Tehan E C,Tao Z,et al.Sol-gel-derived sensor materials that yield linear calibration plots,high sensitivity,and long-term stability[J].Anal.Chem.,2003,75(10):2407-2413.
Carraway E R,Demas J N,DeGraff B A,et al.Photophysics and photochemistry of oxygen sensors based on luminescent transition-mental complexes[J].Anal.Chem.,1991,63(4):337-342.
Bukowski R M,Ciriminna R,Bright F V,et al.High-performance quenchometric oxygen sensors based on fluorinated xerogels doped with[Ru(dpp)3]2+[J].Anal.Chem.,2005,77(8):2670-2672.
Zhang P,Guo J H,Wang Y,et al.Incorporation of luminescent tris(bipyridine)ruthenium(Ⅱ) complex in mesoporous silica spheres and their spectroscopic and oxygen-sensing properties[J].Mater.Lett.,2002,53(6):400-405.
Innocenzi P,Kozuka H,Yoko T,et al.Fluorescence properties of the Ru(bpy)32+ complex incorporated in sol-gel-derived silica coating films[J].J.Phys.Chem.B,1997,101(13):2285-2291.
Murtagh M T,Shahriari M R,Krihak M.A study of the effects of organic modification and processing technique on the luminescence quenching behavior of sol-gel oxygen sensors based on a Ru(Ⅱ) complex[J].Chem.Mater.,1998,10(12):3862-3869.
Fuller Z J,Bare W D,Kneas K A,et al.Photostability of luminescent ruthenium(Ⅱ) complexes in polymers and in solution[J].Anal.Chem.,2003,75(11):2670-2677.
Amouyal E,Homis A,Chambron J C,et al.Synthesis and study of a mixed-ligand ruthenium(Ⅱ) complex in its ground and excited states:bis(2,2-bipyridine)(dipyrido[3,3-a:2,3-c] phenazine-N4N5) ruthenium(Ⅱ)[J].J.Chem.Soc.,Dalton Trans.,1990,(6):1841-1845.
Chen X,Li Z,Jiang Y Q,et al.Oxygen sensing film based on organically modified sol-gel with ruthenium complexes and their fluorescent spectra studies[J].Spectroscopy and Spectral Analysis(光谱学与光谱分析),2002,22(5):796-799 (in Chinese).
Marco G D,Lanza M,Campagna S,et al.Luminescent RuⅡ-polypyridine complexes in poly-2-hydroxyethylmethacrylate matrices as oxygen sensors[J].Adv.Mater.,1995,7(5):468-471.
0
浏览量
273
下载量
0
CSCD
关联资源
相关文章
相关作者
相关机构
京公网安备11010802024621