Estudo de sondagem fluorescente de Eu/Tb-MOFs construídos com ligantes de ácido piridilcarboxílico para Fe3+ e Cr2O<inline-formula><alternatives><math xmlns:mml="http://www.w3.org/1998/Math/MathML" id="M1"><msubsup><mrow/><mrow><mn mathvariant="normal">7</mn></mrow><mrow><mn mathvariant="normal">2</mn><mo>-</mo></mrow></msubsup></math><graphic specific-use="big" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="alternativeImage/34A39A9D-6DED-4eba-AE32-C596D853238B-M001.jpg"/><?fx-imagestate width="3.80999994" height="7.45066643"?><graphic specific-use="small" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="alternativeImage/34A39A9D-6DED-4eba-AE32-C596D853238B-M001c.jpg"/><?fx-imagestate width="3.80999994" height="7.45066643"?></alternatives></inline-formula>

YANG Xiaomin ,  

TANG Yuzhe ,  

SUN Jing ,  

LI Xiao ,  

摘要

Íons de metais pesados (Fe3+) e ânions dicromato (Cr2O<inline-formula><alternatives><math xmlns:mml="http://www.w3.org/1998/Math/MathML" id="M3"><msubsup><mrow/><mrow><mn mathvariant="normal">7</mn></mrow><mrow><mn mathvariant="normal">2</mn><mo>-</mo></mrow></msubsup></math><graphic specific-use="big" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="alternativeImage/34A39A9D-6DED-4eba-AE32-C596D853238B-M003.jpg"/><?fx-imagestate width="1.86266661" height="3.89466691"?><graphic specific-use="small" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="alternativeImage/34A39A9D-6DED-4eba-AE32-C596D853238B-M003c.jpg"/><?fx-imagestate width="1.86266661" height="3.89466691"?></alternatives></inline-formula>) representam uma séria ameaça ao ecossistema aquático e à saúde humana, sendo urgente o desenvolvimento de métodos de detecção eficientes e sensíveis. As sondas fluorescentes baseadas em estruturas metal-orgânicas de lantânio (Ln-MOFs) têm atraído grande atenção neste campo. Neste trabalho, foi utilizado o método solvotérmico, com o ácido 2,2'-bipiridina-4,4'-dicarboxílico (H2BPDC) como ligante, para construir dois novos Ln-MOFs isomórficos com Eu3+ e Tb3+, com fórmulas moleculares C24H16N6O14Eu2 (CUST-1023) e C24H16N6O14Tb2 (CUST-1024), respectivamente. O estudo dos espectros de fluorescência mostrou que ambos podem servir como sondas fluorescentes altamente seletivas para Fe3+ e Cr2O<inline-formula><alternatives><math xmlns:mml="http://www.w3.org/1998/Math/MathML" id="M4"><msubsup><mrow/><mrow><mn mathvariant="normal">7</mn></mrow><mrow><mn mathvariant="normal">2</mn><mo>-</mo></mrow></msubsup></math><graphic specific-use="big" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="alternativeImage/34A39A9D-6DED-4eba-AE32-C596D853238B-M003.jpg"/><?fx-imagestate width="1.86266661" height="3.89466691"?><graphic specific-use="small" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="alternativeImage/34A39A9D-6DED-4eba-AE32-C596D853238B-M003c.jpg"/><?fx-imagestate width="1.86266661" height="3.89466691"?></alternatives></inline-formula> com alta seletividade, com CUST-1024 apresentando melhor sensibilidade e limites de detecção (LOD, limite de detecção) tão baixos quanto 1,87 μmol/L (Fe3+) e 2,52 μmol/L (Cr2O<inline-formula><alternatives><math xmlns:mml="http://www.w3.org/1998/Math/MathML" id="M5"><msubsup><mrow/><mrow><mn mathvariant="normal">7</mn></mrow><mrow><mn mathvariant="normal">2</mn><mo>-</mo></mrow></msubsup></math><graphic specific-use="big" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="alternativeImage/34A39A9D-6DED-4eba-AE32-C596D853238B-M003.jpg"/><?fx-imagestate width="1.86266661" height="3.89466691"?><graphic specific-use="small" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="alternativeImage/34A39A9D-6DED-4eba-AE32-C596D853238B-M003c.jpg"/><?fx-imagestate width="1.86266661" height="3.89466691"?></alternatives></inline-formula>). A espectroscopia de absorção UV-Visível, espectroscopia de infravermelho, difração de raios X em pó e análise do tempo de vida da fluorescência confirmaram que o mecanismo de extinção da fluorescência é principalmente devido à sobreposição eficaz da banda de absorção UV do analito com o espectro de excitação dos MOFs, induzindo a absorção competitiva de energia e extinção dinâmica. Este estudo fornece uma estratégia viável para projetar e sintetizar novos materiais emissores para a detecção de íons metálicos pesados e ânions oxigenados em água. CUST-1023 e CUST-1024 podem servir como materiais sensores fluorescentes potenciais para detectar Fe3+ e Cr2O<inline-formula><alternatives><math xmlns:mml="http://www.w3.org/1998/Math/MathML" id="M6"><msubsup><mrow/><mrow><mn mathvariant="normal">7</mn></mrow><mrow><mn mathvariant="normal">2</mn><mo>-</mo></mrow></msubsup></math><graphic specific-use="big" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="alternativeImage/34A39A9D-6DED-4eba-AE32-C596D853238B-M003.jpg"/><?fx-imagestate width="1.86266661" height="3.89466691"?><graphic specific-use="small" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="alternativeImage/34A39A9D-6DED-4eba-AE32-C596D853238B-M003c.jpg"/><?fx-imagestate width="1.86266661" height="3.89466691"?></alternatives></inline-formula>.

关键词

Ligante de ácido piridilcarboxílico; Estruturas metal-orgânicas de lantânio: sondagem fluorescente

阅读全文

以上内容由讯飞翻译自动生成,翻译内容仅供参考。对于因使用本网站翻译内容产生的相关后果,本网站不承担任何商业和法律责任。

The above content is generated by Large Model Translation. The translated content is for reference only. We do not assume any commercial or legal responsibilty for any consequences arising from the use of our website