Fluoreszenzsensorstudie von Eu/Tb-MOFs basierend auf Pyridin-Carbonsäureliganden für Fe3+ und Cr2O<inline-formula><alternatives><math xmlns:mml="http://www.w3.org/1998/Math/MathML" id="M1"><msubsup><mrow/><mrow><mn mathvariant="normal">7</mn></mrow><mrow><mn mathvariant="normal">2</mn><mo>-</mo></mrow></msubsup></math><graphic specific-use="big" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="alternativeImage/34A39A9D-6DED-4eba-AE32-C596D853238B-M001.jpg"/><?fx-imagestate width="3.80999994" height="7.45066643"?><graphic specific-use="small" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="alternativeImage/34A39A9D-6DED-4eba-AE32-C596D853238B-M001c.jpg"/><?fx-imagestate width="3.80999994" height="7.45066643"?></alternatives></inline-formula>

YANG Xiaomin ,  

TANG Yuzhe ,  

SUN Jing ,  

LI Xiao ,  

摘要

Schwermetallionen (Fe3+) und Dichromat-Anionen (Cr2O<inline-formula><alternatives><math xmlns:mml="http://www.w3.org/1998/Math/MathML" id="M3"><msubsup><mrow/><mrow><mn mathvariant="normal">7</mn></mrow><mrow><mn mathvariant="normal">2</mn><mo>-</mo></mrow></msubsup></math><graphic specific-use="big" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="alternativeImage/34A39A9D-6DED-4eba-AE32-C596D853238B-M003.jpg"/><?fx-imagestate width="1.86266661" height="3.89466691"?><graphic specific-use="small" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="alternativeImage/34A39A9D-6DED-4eba-AE32-C596D853238B-M003c.jpg"/><?fx-imagestate width="1.86266661" height="3.89466691"?></alternatives></inline-formula>) stellen eine ernsthafte Bedrohung für aquatische Ökosysteme und die menschliche Gesundheit dar und erfordern die Entwicklung effizienter und sensitiver Nachweismethoden. Fluoreszenzsonden auf Basis von Lanthanoid-Metall-Organischen Gerüsten (Ln-MOFs) erhalten in diesem Bereich große Aufmerksamkeit. In dieser Arbeit wurde die solvothermale Methode eingesetzt, wobei 2,2'-Bipyridin-4,4'-dicarbonsäure (H2BPDC) als Ligand verwendet wurde, um zwei neue isomorphe Ln-MOFs mit Eu3+ und Tb3+ zu synthetisieren, mit den Molekularformeln C24H16N6O14Eu2 (CUST-1023) bzw. C24H16N6O14Tb2 (CUST-1024). Fluoreszenzspektroskopische Untersuchungen zeigten, dass beide als hochselektive Fluoreszenzsonden für Fe3+ und Cr2O<inline-formula><alternatives><math xmlns:mml="http://www.w3.org/1998/Math/MathML" id="M4"><msubsup><mrow/><mrow><mn mathvariant="normal">7</mn></mrow><mrow><mn mathvariant="normal">2</mn><mo>-</mo></mrow></msubsup></math><graphic specific-use="big" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="alternativeImage/34A39A9D-6DED-4eba-AE32-C596D853238B-M003.jpg"/><?fx-imagestate width="1.86266661" height="3.89466691"?><graphic specific-use="small" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="alternativeImage/34A39A9D-6DED-4eba-AE32-C596D853238B-M003c.jpg"/><?fx-imagestate width="1.86266661" height="3.89466691"?></alternatives></inline-formula> dienen können, wobei CUST-1024 eine bessere Empfindlichkeit zeigt, mit Nachweisgrenzen (LOD, Nachweisgrenze) von nur 1,87 μmol/L (Fe3+) bzw. 2,52 μmol/L (Cr2O<inline-formula><alternatives><math xmlns:mml="http://www.w3.org/1998/Math/MathML" id="M5"><msubsup><mrow/><mrow><mn mathvariant="normal">7</mn></mrow><mrow><mn mathvariant="normal">2</mn><mo>-</mo></mrow></msubsup></math><graphic specific-use="big" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="alternativeImage/34A39A9D-6DED-4eba-AE32-C596D853238B-M003.jpg"/><?fx-imagestate width="1.86266661" height="3.89466691"?><graphic specific-use="small" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="alternativeImage/34A39A9D-6DED-4eba-AE32-C596D853238B-M003c.jpg"/><?fx-imagestate width="1.86266661" height="3.89466691"?></alternatives></inline-formula>). UV-Vis-Absorptionsspektren, Infrarotspektroskopie, pulverröntgenbeugung und Fluoreszenzlebensdauermessungen bestätigten, dass der Fluoreszenzlöschmechanismus hauptsächlich auf die effektive Überlappung des UV-Absorptionsbandes des Analyten mit dem Anregungsspektrum der MOFs zurückzuführen ist, was zu konkurrenzfähiger Energieabsorption und dynamischer Löschung führt. Diese Studie bietet eine praktikable Strategie zur Entwicklung neuer lumineszierender Materialien für den Nachweis von Schwermetallionen und sauerstoffhaltigen Anionen im Wasser. CUST-1023 und CUST-1024 können als potenzielle fluoreszierende Sensormaterialien für den Nachweis von Fe3+ und Cr2O<inline-formula><alternatives><math xmlns:mml="http://www.w3.org/1998/Math/MathML" id="M6"><msubsup><mrow/><mrow><mn mathvariant="normal">7</mn></mrow><mrow><mn mathvariant="normal">2</mn><mo>-</mo></mrow></msubsup></math><graphic specific-use="big" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="alternativeImage/34A39A9D-6DED-4eba-AE32-C596D853238B-M003.jpg"/><?fx-imagestate width="1.86266661" height="3.89466691"?><graphic specific-use="small" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="alternativeImage/34A39A9D-6DED-4eba-AE32-C596D853238B-M003c.jpg"/><?fx-imagestate width="1.86266661" height="3.89466691"?></alternatives></inline-formula>.

关键词

Pyridin-Carbonsäure-Ligand; Lanthanoid-Metall-Organische Gerüste: Fluoreszenzsensorik

阅读全文

以上内容由讯飞翻译自动生成,翻译内容仅供参考。对于因使用本网站翻译内容产生的相关后果,本网站不承担任何商业和法律责任。

The above content is generated by Large Model Translation. The translated content is for reference only. We do not assume any commercial or legal responsibilty for any consequences arising from the use of our website