浏览全部资源
扫码关注微信
1. 浙江大学工业控制技术国家重点实验室 工业控制研究所,浙江 杭州,310027
2. 海南出入境检验检疫局,海南 海口,570311
收稿日期:2011-12-26,
修回日期:2012-01-16,
网络出版日期:2012-03-10,
纸质出版日期:2012-03-10
移动端阅览
杜树新, 杜阳锋, 袁之报. 三维荧光光谱的特征区域选择方法[J]. 发光学报, 2012,33(3): 341-345
DU Shu-xin, DU Yang-feng, YUAN Zhi-bao. Characteristic Region Selection Methods for Three-dimensional Fluorescence Spectrometry[J]. Chinese Journal of Luminescence, 2012,33(3): 341-345
杜树新, 杜阳锋, 袁之报. 三维荧光光谱的特征区域选择方法[J]. 发光学报, 2012,33(3): 341-345 DOI: 10.3788/fgxb20123302.0341.
DU Shu-xin, DU Yang-feng, YUAN Zhi-bao. Characteristic Region Selection Methods for Three-dimensional Fluorescence Spectrometry[J]. Chinese Journal of Luminescence, 2012,33(3): 341-345 DOI: 10.3788/fgxb20123302.0341.
将数学中的二元凸函数判定和数据挖掘中的聚类分析方法结合
提出了针对三维荧光的光谱区域选择方法
并利用此种方法从光谱图中提取出含有丰富光谱信息的凸集区域。对水体中总有机碳的检测和白酒中黄曲霉素的检测进行了实验研究
实验结果表明
采用本文提出的三维荧光光谱区域选择方法提高了模型的精度
与利用全光谱所建立的回归模型相比
模型精度分别提高了6.17%和4.97%。
Based on combination of binary convex function discriminant theorem with clustering analysis
a new method of characteristic region selection for three-dimensional fluorescence spectrometry is proposed. By this method
the convex regions with valid spectral data are obtained.Experiment for detecting total organic carbon (TOC) in water and AFB1 in liquor are carried out. The experimental results show that the proposed method improves the accuracy of the regress model with increase of 6.17% and 4.97% respectively.
Wu W, Walczak B, Massart D L, et al. Spectral transformation and wavelength selection in near-infrared spectra classification [J]. Analytica Chimica Acta, 1995, 315(3):243-255.[2] Leardi R. Application of genetic algorithm-PLS for feature selection in spectral data set [J]. J. Chem., 2000, 14:643-655.[3] Norgaard L, Saudland A, Wagner J, et al. Interval partial least-squares regression (iPLS): A comparative chemometirc study with an example from near-infrared spectroscopy [J]. Applied Spectroscopy, 2000, 54(3):413-419.[4] Zhang Xuemao. Convex function of the equivalent binary form of discrimenant [J]. J. Langfang Teachers College (Naturnal Science Edition) (廊坊师范学院学报,自然科学版), 2011, 11(4):18-21 (in Chinese).[5] Du Shuxin, Du Yangfeng, Wu Xiaoli. Detection of dissolved organic matter based on three-dimensional first-order derivative fluorescence spectrometry [J]. Spectroscopy and Spectral Analysis (光谱学与光谱分析), 2010, 30(12):3268-3271 (in Chinese).[6] Cheng Guoqing, Chen Xiaoyun. Clustering algorithm for multi-density based on grid relative density [J]. Computer Engineering and Applications (计算机工程与应用), 2009, 45(1):156-159 (in Chinese).[7] Lai Bo, Zhou Yuexi, Li Zhijun, et al. The variation trend of fluorescence characteristics of aromatic organic pollutants in the three-phase three-dimensional electrode reactor [J]. Chin. J. Lumin.(发光学报), 2011, 32(3):300-306 (in Chinese).