王乐新, 赵志敏. 正常和异常血清的共振散射光谱[J]. 发光学报, 2011,32(2): 200-204
WANG Le-xin, ZHAO Zhi-min. Resonance Scattering Spectra of Normal Serums and Abnormal Serums[J]. Chinese Journal of Luminescence, 2011,32(2): 200-204
用日本岛津RF-5301荧光分光光度计研究了高甘油三脂、高胆固醇、高血糖血清和正常血清的散射光谱及同一生化指标不同浓度血清散射光谱的规律。实验结果表明
正常血清散射光谱与高血脂和高血糖血清散射光谱的特征峰差异明显
可以据此区分正常和高血糖、高血脂血清;同一生化指标不同浓度血清散射光谱的峰值强度随血脂、血糖浓度的增大而增强
峰值强度
I
446
/
I
464
和
I
615
/
I
628
的值随血糖浓度的增大近似呈线性变化
而高血脂血清的散射光谱则无此现象
据此可区分高血糖和高血脂血清。此研究为临床医学应用提供了可靠的实验依据。
The scattering spectra of high triglycerides
high cholesterol
high blood sugar and normal serum were researched with Shimadzu RF-5301 fluorescence spectrophotometer
and the scattering spectra of serums with same biochemical parameters. The scattering spectra of abnormal serums
such as the serums with hyperlipidemia and the serums with hyperglycemia
have obvious differences from the spectra of normal serums at the characteristic peaks. This result has laid the foundation of distinguishing between normal and high blood sugar
high blood lipids serum. The peak intensity of scattering spectra in the same biochemical markers of different concentrations serum increased with the blood lipids
blood glucose concentrations.Moreover
the peak intensity ratio of
I
446
/
I
464
and
I
615
/
I
628
increased with blood sugar concentration
and has a nearly linear relationship. However
there is no similar phenomenon in the scattering spectra of serums with hyperlipidemia. Hence
it can be used to distinguish between the serums with hyperglycemia and the serums with hyperlipidemia. This study provides an experimental basis for clinical application.
Luo Xiaosen, Ni Xiaowu, Lu Jian, et al. Study of fluorescent spectrum of blood induced by light of different wavelengths[J]. Chin. J. Lasers (中国激光), 2003, 30 (1):93-96 (in Chinese).[2] Wang Lexin, Zhao Zhmin, Guo Linfeng, et al. Experimental investigation and application of low luminescence of serum[J]. Chin. J. Lasers (中国激光), 2008, 35 (5):797-800 (in Chinese).[3] Liu Baosheng, Xue Chunli, Wang Jing, et al. Studies on the interaction between ciprofloxacin and ofloxacin in presence of boving serum albumin by spectroscopic methods [J]. Chin. J. Lumin. (发光学报), 2010, 31 (2):285-290 (in Chinese).[4] Chen Kun. Studies on characteristics of Rayleigh scatter spectrum of in vivo phytoplankton . Qingdao: Ocean University of China, 2007.[5] Ling Shaoming, LI Jishun, Wen Guiqing. Resonance scattering spectral analysis of melamine [J]. Analysis and Testing Technology and Instruments (分析测试技术与仪器), 2009, 15 (3):140-143 (in Chinese).[6] Sun Shuangjiao, Liang Aihui, Jiang Zhiliang, et al. A simple and sensitive immune resonance scattering spectral assay for determination of fibrinogen [J]. Chin. J. Appl. Chem.(应用化学), 2009, 26 (4):451-454 (in Chinese).[7] Jiang Ting. Application of resonance light scattering in the determination of pesticides and food additives . Nanchang:Nanchang University, 2007.[8] Men Weiwei. Study on the new determination method for antiviral and cardiovascular drugs by fluorescence and resonance scattering technique . Chongqing: Southwest University, 2009.[9] Qin M, Liu S, Liu Z, et al. Resonance Rayleigh scattering spectra, non-linear scattering spectra of tetracaine hydrochloride-erythrosin system and its analytical application [J]. Spectrochim. Acta A: Mol. Biomol. Spectrosc., 2009, 71 (5):2063-1-8.[10] Luo J G, Liu Z F, Kong L, et al. Study on the resonance Rayleigh scattering and resonance non-linear scattering spectra of ion-association complexes of (2-)-protein systems and their analytical applications [J]. J. Lumin., 2009, 24 (6):429-437.[11] Zhan G, Zhang L, Li C. Resonance light scattering spectral method for the determination of serum albumin with the inte-raction of neutral red-sodium dodecyl sulfonate [J]. Colloids Surf. B: Biointerfaces, 2009, 71 (1):84-1-7.[12] Yang Chuanxiao, Li Yuanfang, Huang Chengzhi. Determination of total protein content in human blood plasma samples with ponceau G by resonance light scattering technique [J]. Chin. J. Analytical Chemistry (分析化学), 2003, 31 (2):148-152 (in Chinese).[13] Wang Xin, Liu Jin-shui, Wang Lun. Resonance scattering spectrometric determination of human serum albumin [J]. Phys. Testing and Chem. Analysis (理化检验), 2006, 24 (4):257-259 (in Chinese).[14] Xie Jiyun, Jiang Zhiliang, Zhong Fuxin, et al. Spectral properties of blood cell [J]. Analysis and Testing Technology and Instruments (分析测试技术与仪器), 2000, 6 (3):178-181 (in Chinese).[15] Hu Yong, Fu Xiong, Chen Xudong, et al. Interaction between potassium sorbate and bovine serum albumin revealed by fluorescence and resonance light scattering spectra [J]. Acta Scientiarum Naturalium Universitatis Sunyatseni (中山大学学报,自然科学版), 2009, 48 (6):73-78 (in Chinese).[16] Yang Qingling. Study of the application to determine biomacromolecule by resonance light-scattering spectroscopy .Chong Qing: Southwest University, 2008.