BU Ren-an, CAI Hong-hong, ZHANG Jin-tao. Measurement Method for Second Luminescence Characteristics of Phosphors for Color PDP[J]. Chinese Journal of Luminescence, 2002,23(2): 201-205
BU Ren-an, CAI Hong-hong, ZHANG Jin-tao. Measurement Method for Second Luminescence Characteristics of Phosphors for Color PDP[J]. Chinese Journal of Luminescence, 2002,23(2): 201-205DOI:
设计制作了测试PDP屏三基色荧光粉发光色坐标所用的单色试验屏。用CRT Color Analyzer(CA-100)对PDP屏和PDP屏上气体放电产生的亮度和色坐标都进行了测量
根据合成颜色的三刺激值与二种已知颜色的三刺激值具有线性叠加关系
计算出了荧光粉在PDP器件中的色坐标和亮度。同时
用WGD-3型组合式多功能光栅光谱仪对PDP屏和气体放电的发光光谱进行了测量
用计算机将测得的发光光谱在同波长下相减
从而获得了荧光粉在PDP屏中的发光光谱。结果表明绿粉和蓝粉的色坐标变化较大
而红粉变化较小
使得PDP白场色温向较低的方向变化。绿粉和蓝粉的发光谱线的半峰宽与原粉比较都有减小
峰值发光强度也减小了
绿粉的峰值发光波长从526nm变至523.4nm。
Abstract
Color Plasma Display Panels (PDPs) is one of the important developing trends in the flat display field. The chromaticity coordinates measured on the PDP include two parts: the first part is chromaticity coordinate of phosphor on the PDP device
another is the chromaticity coordinate of gas discharge during the operation of PDP. In the process of fabricating a PDP
phosphor undergo the process of paste preparation
drying
sintering and aging etc. The chromaticity coordinates presented on the panel of PDP is thus somewhat different from that of raw phosphor. The aim of this paper is to measure the chromaticity coordinates of phosphor lighting. A new method is presented to obtain the chromaticity coordinates and brightness of phosphor on PDP by using the chromaticity coordinates and brightness of a monocolor and chromaticity coordinates and brightness of gas discharge under the same structure. A monocolor test panel is designed and fabricated for measuring the chromaticity coordinates of trichromatic phosphor lighting of PDP. The brightness and chromaticity coordinates of PDP and the brightness and chromaticity coordinates of gas discharge of PDP are all measured by using CRT Color Analyzer(CA-100). The chromaticity coordinates and brightness of phosphor on PDP is computed based on the linear superposition relation of tri-stimulus value of compound color and the tri-stimulus value of two known colors. At the same time
luminescence spectrum of PDP panel and gas discharge is measured with assembled multi-function raster spectrometer of WGD-3 type. The difference of two measured luminescence spectrum at the same wavelength is the luminescence spectrum of phosphor on PDP panel. The results show that the variation of chromaticity coordinates of green and blue phosphor is large and for red phosphor it is small which makes the white color temperature of PDP varies toward to the lower direction. The widths at half peak of luminescence spectrum of green and blue phosphor are both smaller than that of original phosphor. The peak luminous intensity is also decreased. The peak luminescence wavelength of green phosphor become 523.4nm from 526nm.