针对荧光峰值法浓度测量中最佳激发和发射波长的选择问题,提出基于三维荧光光谱的多峰线性回归参数比较法。以市售93号和97号汽油为例,首先利用FS920型稳态荧光光谱仪扫描纯水和纯油品的三维荧光光谱,确定特征荧光峰峰位和强度;其次按不同体积比分别配置7种浓度的油水混合液样品,提取不同样品的荧光峰峰位、强度等特征参量,发现浓度对荧光峰特征参量有较大干扰;然后用排除法确定了93号和97号油水混合液样品分别有23个和22个特征峰;最后采用最小二乘法对每个峰的强度与浓度作线性回归,通过对校正决定系数、
F
值、灵敏度和截距等参数的比较得出,93号和97号油水混合液的最佳激发/发射波长分别为275/302 nm和285/322 nm。实验结果表明,根据最佳峰校正模型,93号和97号汽油浓度测量的绝对误差分别为0.006、0.007,比传统的最强峰校正模型精度高1个数量级。
For selecting optimal fluorescence excitation and emission wavelength of peak value method of concentration measurement
a multiple peaks linear regression parameters comparison method based on 3D fluorescence spectra was proposed. Taking 93# and 97# motor gasoline in the market for examples
firstly
3D fluorescence spectra of purified water and motor gasoline from FS920 steady-state fluorescence spectrometers were analyzed and the characteristic fluorescence peaks were found. Secondly
7 kinds of mixed liquors of 93# and 97# gasoline and water were prepared by volume ratio
respectively. Peak position and intensity
etc
. parameters of different sample were extracted. Results show that the characteristic fluorescence peak parameters are different for the different concentration. And then
for the mixed liquors of 93# and 97# gasoline and water
23 peaks and 22 peaks were found by the exclusive method
respectively. Finally
the peak intensity and concentration data of each sample were fit by using the least square method. The comparison of adj. R-Square
F
value
sensitivity and intercept
etc
. shows that the optimal excitation/emission wavelength of 93# and 97# gasoline sample is 275/302 nm and 285/322 nm
respectively. Experimental results show that the absolute error of 93# and 97# concentration is 0.006 and 0.007
respectively. The precision of the calibration model founded by the optimal peak is one order higher than the traditional calibration model founded by the strongest peak.
王娟娟, 孙友宝, 马晓玲, 等. 傅里叶变换红外光谱仪测试水中油含量[J]. 环境化学, 2015, 34(2):399-400. WANG JJ, SUN Y B, MA X L, et al.. Oil-in-water measurement using FTIR spectrometer[J]. Environment. Chem., 2015, 34(2):399-400. (in Chinese)
高志帆, 曾立波, 石磊, 等. 基于MEMS线阵的便携式中红外水中油浓度速测仪[J]. 光谱学与光谱分析, 2014, 34(6):1711-1715. GAO Z F, ZENG L B, SHI L, et al.. Development of a portable mid-infrared rapid analyzer for oil concentration in water based on MEMS linear sensor array[J]. Spectrosc. Spect. Anal., 2014, 34(6):1711-1715. (in Chinese)
张慧英, 赵天波, 李凤艳. 气相色谱-质谱联用技术测定水中油[J]. 分析科学学报, 2003, 19(5):99-100. ZHANG H Y, ZHAO T B, LI F Y. Determination of oil in water by gas chromatography-mass spectrometry[J]. J. Anal. Sci., 2003, 19(5):99-100. (in Chinese)
赵友全, 邹瑞杰, 陈玉榜, 等. 近红外散射法测定水中矿物油含量研究[J]. 光谱学与光谱分析, 2012, 32(5):1213-1216. ZHAO Y Q, ZOU R J, CHEN Y B, et al.. Research on detection of oil in water based on near-infrared scattering method[J]. Spectrosc. Spect. Anal., 2012, 32(5):1213-1216. (in Chinese)
崔志成, 刘文清, 赵南京, 等. 水中油浓度快速测量方法研究[J]. 光谱学与光谱分析, 2008, 28(6):1332-1335. CUI Z C, LIU W Q, ZHAO N J, et al.. Study on the method for rapid determination of oil concentration in water[J]. Spectrosc. Spect. Anal., 2008, 28(6):1332-1335. (in Chinese)
陆从文, 兰秀风, 张林, 等. 依巴斯汀与牛血清蛋白相互作用的荧光光谱研究[J]. 光子学报, 2015, 44(10):1030004. LU C W, LAN X F, ZHANG L, et al.. Interaction between ebastine and bovine serum albumin by fluorescence spectroscopy[J]. Acta Photon. Sinica, 2015, 44(10):1030004. (in Chinese)
赵曼彤, 李柏承, 周瑶, 等. 香梨表面低浓度农药残留高光谱检测研究[J]. 光学技术, 2016(5):408-412. ZHAO M T, LI B C, ZHOU Y, et al.. Detection of low concentration pesticide residue on pears by hyperspectral image technology[J]. Opt. Tech., 2016(5):408-412. (in Chinese)
吴元清, 杜树新, 严赟. 水体有机污染物浓度检测中的紫外光谱分析方法[J]. 光谱学与光谱分析, 2011, 31(1):233-237. WU Y Q, DU S X, YAN Y. Ultraviolet spectrum analysis methods for detecting the concentration of organic pollutants in water[J]. Spectrosc. Spect. Anal., 2011, 31(1):233-237. (in Chinese)
王志刚, 刘文清, 张玉钧, 等. 三维荧光光谱法分类测量水体浮游植物浓度[J]. 中国环境科学, 2008, 28(2):136-141. WANG Z G, LIU W Q, ZHANG Y J, et al.. The classified measuring of three dimensional excitation-emission fluorescence matrix technique on phytoplankton concentration in water body[J]. China Environment. Sci., 2008, 28(2):136-141. (in Chinese)
丁志群, 王金霞, 赵洪霞, 等. 基于三维荧光光谱技术的食用油快速分析研究[J]. 光子学报, 2015, 44(6):0630004. DING Z Q, WANG J X, ZHAO H X, et al.. Rapid analysing edible oil using three dimensional fluorescence spectroscopy[J]. Acta Photon. Sinica, 2015, 44(6):0630004. (in Chinese)
王乐新, 赵志敏, 辛玉军, 等. 不同波长激发光对血清荧光光谱影响的实验研究[J]. 光谱学与光谱分析, 2008, 28(10):2360-2364. WANG L X, ZHAO Z M, XIN Y J, et al.. Experimental investigation of fluorescence spectra of serum excitated with different wavelength light[J]. Spectrosc. Spect. Anal., 2008, 28(10):2360-2364. (in Chinese)
李向军, 韩桂茹, 李晓燕, 等. 薄层扫描测定中荧光与增荧光成分的最佳激发波长研究[J]. 河北中医药学报, 2013(2):42-43. LI X J, HAN G R, LI X Y, et al.. Study of best excitation wave length of fluorescence and fluorescence increase components in thin slice scan and detection[J]. J. Heibei TCM and Pharmacol., 2013(2):42-43. (in Chinese)
何清杭, 张镇西, 王晶. 基于指示克立格法的最佳激发波长和最佳发射波长的确定[J]. 光谱学与光谱分析, 2007, 27(8):1476-1479. HE Q H, ZHANG Z X, WANG J. Confirmation of optimal excitation and emission wavelengths based on indicator Kriging method[J]. Spectrosc. Spect. Anal., 2007, 27(8):1476-1479. (in Chinese)
鄢远, 王乐天, 林竹光, 等. 三维荧光光谱总体积积分法同时测定多环芳烃[J]. 高等学校化学学报, 1995, 16(10):1519-1522. YAN Y, WANG L T, LIN Z G, et al.. Three-dimensional fluorescence spectrometry and its application to simultaneous determination of polyaromatic hydrocarbons by detecting total fluorescence intensity[J]. Chem. J. Chin. Univ., 1995, 16(10):1519-1522. (in Chinese)
鄢远, 王乐天, 许金钩, 等. 三维导数荧光光谱总体积积分法同时测定多环芳烃[J]. 化学学报, 1996, 54:772-776. YAN Y, WANG L T, XU J G, et al.. Three-Dimensional derivative-fluorescence spectrometry and its application to simultaneous determination of polyaromatic hydrocarbons by detecting total fluorescence intensity[J]. Acta Chim. Sinica, 1996, 54:772-776. (in Chinese)
徐婧, 侯培国, 王玉田, 等. 基于特征峰值积分法的调和油组分含量的测量[J]. 光谱学与光谱分析, 2016, 36(1):298-302. XU J, HOU P G, WANG Y T, et al.. Determination of component contents of blend oil based on characteristics peak value integration[J]. Spectrosc. Spect. Anal., 2016, 36(1):298-302. (in English)
王春艳, 江华鸿, 高居伟, 等. 基于三维同步荧光光谱确定原油样品浓度的新方法[J]. 光谱学与光谱分析, 2006, 26(6):1080-1083. WANG C Y, JIANG H H, GAO J W, et al.. A new method for concentration determination of crude oil sample using three dimensional synchronous fluorescence spectra[J]. Spectrosc. Spect. Anal., 2006, 26(6):1080-1083. (in Chinese)
WANG C, SHI X, LI W, et al.. Oil species identification technique developed by gabor wavelet analysis and support vector machine based on concentration-synchronous-matrix-fluorescence spectroscopy[J]. Marine Pollution Bull., 2016, 104(1-2):322-328.
李宏斌, 刘文清, 王志刚, 等. 基于三维荧光光谱技术的多组分分析浓度校准方法研究[J]. 量子电子学报, 2007, 24(3):306-310. LI H B, LIU W Q, WANG Z G, et al.. Concentration calibration of multi-component analysis based on three-dimensional fluorescence spectroscopy[J]. Chin. J. Quant. Electron., 2007, 24(3):306-310. (in Chinese)
王书涛, 陈东营, 魏蒙, 等. 荧光光谱法和PSO-BP神经网络在山梨酸钾浓度检测中的应用[J]. 中国激光, 2015, 42(5):304-310. WANG S T, CHEN D Y, WEI M, et al.. Application of fluorescence spectroscopy and PSO-BP neural network in the detection of potassium sorbate concentration[J]. Chin. J. Lasers, 2015, 42(5):304-310. (in Chinese)
王书涛, 陈东营, 王兴龙, 等. 种荧光光谱法和PSO-BP神经网络相结合的山梨酸钾浓度测定的新方法[J]. 光谱学与光谱分析, 2015, 35(12):3549-3554. WANG S T, CHEN D Y, WANG X L, et al.. A new method for the determination of potassium sorbate combining fluorescence spectra method with PSO-BP neural network[J]. Spectrosc. Spect. Anal., 2015, 35(12):3549-3554. (in English)
黄蕾, 吴海龙, 聂瑾芳, 等. 三维荧光光谱结合二阶校正算法用于化妆品中芦丁含量的测定[J]. 计算机与应用化学, 2010, 27(7):893-896. HUANG L, WU H L, NIE J F, et al.. Determination of rutin in cosmetics using second-order calibration methods coupled with excitation-emission fluorescence spectra[J]. Comput. Appl. Chem., 2010, 27(7):893-896. (in Chinese)
龙宁, 朱明芳, 吴海龙. 交替三线性分解算法用于萘普生和阿司匹林的同时荧光测定[J]. 广东药学院学报, 2003, 19(2):136-137. LOU N, ZHU M F, WU H L. EX-EM fluorescence determination of NAP and ASA using ATLD algorithm[J]. Academic J. Guangdong College of Pharm., 2003, 19(2):136-137. (in Chinese)
TARAI M, MISHRA A K. Inner filter effect and the onset of concentration dependent red shift of synchronous fluorescence spectra[J]. Anal. Chim. Acta, 2016, 940:113-119.
BENITO-PEA E, VALDS M G, GLAHN-MARTNEZ B, et al.. Fluorescence based fiber optic and planar waveguide biosensors:a review[J]. Anal. Chim. Acta, 2016, 943:17-40.
GHOSH H. A possible route to the violation of Vavilov-Kasha rule in -conjugated polymers[J]. Chem. Phys. Lett., 2006, 426(4):431-435.
金丹, 张玉钧, 李国刚, 等. 四种多环芳烃的三维荧光谱解析[J]. 大气与环境光学学报, 2008, 3(6):448-453. JIN D, ZHANG Y J, LI G G, et al.. Three-dimensional fluorescence spectral analysis of four kinds of polycyclic aromatic hydrocarbons[J]. J. Atmosph. Environment. Opt., 2008, 3(6):448-453. (in Chinese)
肖雪, 张玉钧, 王志刚, 等. 矿物油-乙醇溶液三维荧光光谱的实验研究[J]. 光谱学与光谱分析, 2010, 30(6):1549-1554. XIAO X, ZHANG Y J, WANG Z G, et al.. Experimental studies on three-dimensional fluorescence spectral of mineral oil in ethanol[J]. Spectrosc. Spect. Anal., 2010, 30(6):1549-1554. (in Chinese)