HAN Bing, WU Yan-xiong, CHEN Xiao-ping etc. Structure Design of Laser/Visible Dual-mode Seeker[J]. Chinese Journal of Luminescence, 2014,35(11): 1382-1387
HAN Bing, WU Yan-xiong, CHEN Xiao-ping etc. Structure Design of Laser/Visible Dual-mode Seeker[J]. Chinese Journal of Luminescence, 2014,35(11): 1382-1387 DOI: 10.3788/fgxb20143511.1382.
Structure Design of Laser/Visible Dual-mode Seeker
Laser/visible dual-mode seeker used for precise guidance of missile was designed. In order to reduce the structure volume
RC complex structure of double-channel was used
which shared main mirror and secondary mirror together
and multiple-folding for light transforming was adopted. The focal length and field angle of the visible light path are 100 mm and 3 separately
which are designed for searching the initial goal of the larger region. The focal length and field angle of the laser light path are 300 mm and 0.6 separately
which are designed for confirmation of the final target guided by laser. The computer software was used to optimize the analysis of design. The total quality is less than 600 g. These characteristics of structure design make certain the thermal stability and structural reliability. The results of environmental tests show that the visible MTF is better than 0.3@50 lp/mm
satisfying the end requirements.
关键词
Keywords
references
Li F W, Zhang Y Q, Pan G Q. Optical design of IR/laser dual-mode common aperture system [J]. J. Appl. Opt.(应用光学), 2012, 33(3):496-499 (in Chinese).
Luo H B, Shi Z L. Status and prospect of infrared imaging guidance technology [J]. Infrared Laser Eng.(红外与激光工程), 2009, 38(4):565-573 (in Chinese).
Wang L J, Zhang X, Yang H M, et al. Design of a compact infrared catadioptric system [J]. J. Appl. Opt.(应用光学), 2007, 28(3):288-291 (in Chinese).
Zhang Y M. Applied Optics [M]. Beijing: Electronics Industry Press, 2008.
Claps P, Cullen M, Harris D. Real-time image processing and data fusion of two-channel imaging laser radar sensor [J]. SPIE, 1992, 1533:281-287.
Kinglake R, Johnson R B. Lens Design Fundamentals [M]. 2nd. USA: Academic Press, 1978.
Wang C S, Yu S L, Gao S. A design of staring IR imaging system applied in precise seeker [J]. Laser and Infrared (激光与红外), 2007, 37(4):332-334 (in Chinese).
Di X G, Yao Y, Zhou F Q. Common aperture IR/laser dual-mode imaging seeker system [J]. Infrared Laser Eng.(红外与激光工程), 2005, 34(5):577-581 (in Chinese).
Liu R Q, Chen X M, Zhao J Q. Design of a compact infrared optical system [J]. Laser and Infrared (激光与红外), 2009, 39(4):419-422 (in Chinese).
Zuo B J, Kuang Y W. Optical design of the IR/laser dual-mode imaging seeker [J]. Infrared Laser Eng.(红外与激光工程), 2009, 38(3):495-499 (in Chinese).
Overbeck J A, Shea J J. MTF measurement technique for GOES imager [J]. SPIE, 1998, 3377:155-159.
Lin F T, Liu Z H. MWIR refractive/diffractive hybrid athermal optical system and its stray light analysis [J]. J. Appl. Opt.(应用光学), 2010, 31(5):833-837 (in Chinese).
Stann B, Abou-Auf A, Frankel S, et al. Research progress on scannerless ladar system using a laser diode transmitter FM/CW radar principles [J]. SPIE, 2001, 4377:12-22.
Kim S, Yang H, Lee Y, et al. Merit function regression method for efficient alignment control of two-mirror optical systems [J]. Opt. Express, 2007, 15(8):5059-5069.
Fischer R E, Tadic-Gabeb G B. Optical System Design [M]. New York: McGraw_Hill, 2004.
Growth and Characterization of Tb3Sc2Al3O12 Magneto-optical Crystal
Research Progress of YAG: Ce Fluorescent Films for White Lighting
Compatible Stealth Photonic Crystal for Visible Light, Far Infrared and Lasers
Research on Compatible Stealth Photonic Crystal Against Near/Middle Infrared and 1.06 μm and 1.54 μm Lasers
Studies on Nitrogen-dopped Carbon Nanodots
Related Author
TAO Xu-tang
JIA Zhi-tai
FU Xiu-wei
HAO Yuan-kai
XIN Xian-hui
LIU Lei
HU Qiang-qiang
Li-na LIU
Related Institution
State Key Laboratory of Crystal Materials, Shandong University
School of Materials Science and Engineering, Shandong University of Technology
School of Materials Science and Engineering, Northeastern University
State Key Laboratory of Pulsed Power Laser Technology, College of Electronic Engineering, National University of Defense Technology, Hefei 230037, China
Hefei National Laboratory for Physical Sciences at The Microscale, University of Science and Technology of China, Heifei