CAO Shi-na, LIU Bao-sheng, LI Zhi-yun, CHONG Bao-hong. A Determination Method of Glipizide Content with Bovine Serum Albumin as Fluorescent Probe[J]. Chinese Journal of Luminescence, 2013,34(7): 930-934
CAO Shi-na, LIU Bao-sheng, LI Zhi-yun, CHONG Bao-hong. A Determination Method of Glipizide Content with Bovine Serum Albumin as Fluorescent Probe[J]. Chinese Journal of Luminescence, 2013,34(7): 930-934 DOI: 10.3788/fgxb20133407.0930.
A Determination Method of Glipizide Content with Bovine Serum Albumin as Fluorescent Probe
the reaction between bovine serum albumin (BSA) and Glipizide can lead the fluorescence of BSA quenching regularly. Based on this pheno-menon
a new method that determining the content of Glipizide was established
in which BSA was used as the fluorescent probe. The concentration of Glipizide presented a nice liner relation with the fluorescence intensity from 0.25 to 20 mol/L. The detection limit was 0.071 mol/L. The method was applied to analysis the Glipizide content in drugs samples
and the RSD was from 1.29% to 2.80%
the recovery rate was from 86.79% to 96.43% with six parallel determinations.
关键词
Keywords
references
Li X, Xu Z, Lu X, et al. Comprehensive two-dimensional gas chromatography/time-of-flight mass spectrometry for metabonomics: Biomarker discovery for diabetes mellitus[J]. Anal. Chim. Acta, 2009, 633(2):257-262.[2] AbuRuz S, Millership J, McElnay J. The development and validation of liquid chromatography method for the simultaneous determination of metformin and glipizide, gliclazide, glibenclamide or glimperide in plasma[J]. J. Chromatogr. B, 2005, 817(2):277-286.[3] Kradjan W A, Kobayashi K A, Bauer L A, et al. Glipizide pharmaco-kinetics:effects of age, diabetes, and multiple dosing[J]. J. Clin. Pharmaco., 1989, 29(12):1121-1127.[4] Li X M, Cao W, Wu J P, et al. Pharmacokinetics of compound glipizide and metformin hydrochloride tablets in healthy volunteers[J]. Chin. Hosp. Pharm. J.(中国医院药学杂志), 2007, 27(7):869-872 (in Chinese).[5] Li Q Y, Li X Z, Xu S P. Determination of the plasma concentration of glipizide by HPLC[J]. J. Clin. Res.(医学临床研究), 2005, 22(1):137-138 (in Chinese).[6] Yan S H. An HPLC method for the determination of the concentration of glipizide and the improvement of mobile phase on content uniformity[J]. Guide of China Medicine (中国医药指南), 2010, 8(28):50-51 (in Chinese).[7] Tang J L, Wang L, Xiang R F, et al. Determination of glipizide in human serum by HPLC[J]. Chin. J. Anal. Lab.(分析实验室), 2007, 26(2):84-88 (in Chinese).[8] Feng J, Liu J, Su D, et al. Determination of two components in metformin and glipizide tablets by reversed-phase ion-pair HPLC[J]. Chin. J. New Drugs Clin. Rem.(中国新药与临床杂志), 2010, 29(6):445-447 (in Chinese).[9] Tong R F, Qin X M, Ding L, et al. Analysis of urine excretion of metformin-glipizide tablet after oral administration in healthy human[J]. Tianjin Med. J.(天津医药), 2012, 40(1):7-11 (in Chinese).[10] Zhao X H, Song B, Zhong D F, et al. Simultaneous determination of metformin and glipizide in human plasma by liquid chromatography-tandem mass spectrometry[J]. Acta Pharmaceutica Sinica (药学学报), 2007, 42(10):1087-1091 (in Chinese).[11] Liu Y, Huang L J, Wang J D, et al. Simultaneous determination of three diabetic drugs in urine by high performance liquid chromatography[J]. J. Instrumental. Anal.(分析测试学报), 2011, 30(3):293-297 (in Chinese).[12] Liu B S, Yan X N, Cao S N, et al. Interaction of cefpiramide with bovine serum albumin and the effect of coexistent metal ion on the reaction[J]. Chin. J. Lumin.(发光学报), 2012, 33(9):1018-1024 (in Chinese).[13] Jiang T M, Tan F P, Du J L, et al. Preparation and in vitro release of glipizide loaded controlled release microspheres[J]. J. Tsinghua Univ.(Sci & Tech)(清华大学学报(自然科学版)), 2004, 44(6):732-735 (in Chinese).[14] Tian L F, Liu Z F, Hu X L, et al. Proteins fluorescence quenching by 2- and its analytical application[J]. Chem. J. Chin. Univ.(高等学校化学学报), 2012, 33(1):59-65 (in Chinese).[15] Zhang S, Nie S F, Wei L L, et al. Study on inclusive reaction of water-soluble -cyclodextrin polymer with glipizide[J]. Chin. Pham. J.(中国药学杂志), 2007, 42(8):601-604 (in Chinese).[16] Huang G W, Zhang C P. Suggestion on assay of glipizide tablets[J]. Drug Standard of China (中国药品标准), 2005, 6(2):52-53 (in Chinese).
Advances in Integration of Organic Small Molecule Fluorescent Probes with Electrospinning Techniques for Detection of Explosives
Construction and Application of Zn2+ Fluorescent Probe Based on Coumarin
Fluorescent Probe Derived from 2-(2'-Hydroxyphenyl)-Benzothiazole for Hydrogen Peroxide Sensing: Synthesis, Characterization and Application
Construction and Bioimaging of PPi Fluorescent Probes Based on Iron Complexes
Construction and Properties of Colorimetric Zn2+ Fluorescent Probe Based on Naphthofuran
Related Author
CHENG Leqin
TAO Yunqi
ZHANG Yuewei
YU Xue
WANG Ye
ZHU Xinyue
HUAI Yu
CUI Tong
Related Institution
School of Chemistry and Pharmaceutical Engineering, Jilin Institute of Chemical Technology
College of Chemical Engineering, University of Science and Technology Liaoning
College of Light Chemical Engineering, Guangdong Polytechnic Normal University
Anan Cosmetics and Healthcare Products Co., Ltd.
State Key Laboratory of Integrated Optoelectronics, Jilin Key Laboratory on Advanced Gas Sensor, College of Electronic Science and Engineering, Jilin University