GUO Cheng, GAO Gui-yuan, DING Xiao-jie, LI Jian-jun, YANG Ran, QU Ling-bo. Determination of Diethylstilbestrol in Milk with The Enhanced Chemiluminescence System of Luminol-K<sub>3</sub>Fe(CN)<sub>6</sub> by Using of ZnSe Quantum-dots[J]. Chinese Journal of Luminescence, 2012,33(7): 796-801 DOI: 10.3788/fgxb20123307.0796.
Determination of Diethylstilbestrol in Milk with The Enhanced Chemiluminescence System of Luminol-K3Fe(CN)6 by Using of ZnSe Quantum-dots
It was found that ZnSe quantum dots (QDs) could enhance the chemiluminescence(CL) of the luminol-K
3
Fe(CN)
6
system. The CL from luminol-K
3
Fe(CN)
6
-ZnSe QDs system is strongly inhibited under the presence of hydroquinone. Based on this inhibition
a novel CL method with a lower detection limit and wider linear range was developed for determining diethylstilbestrol. The possible CL mechanism was also discussed. Under the selected experimental conditions
the CL intensity was linear with the concentration of diethylstilbestrol from 6.0×10
-9
mol/L to 4.0×10
-5
mol/L with a detection limit of 2.0×10
-9
mol/L(
S/N
=3). The relative standard deviation(RSD)(
n
=11)for the determination of 4.0×10
-6
mol/L diethylstilbestrol was 1.4%.The proposed method was successfully applied to analyze diethylstilbestrol in milk samples with recoveries of 94.47%~ 107.61%.
关键词
Keywords
references
Pfaffi M W, Reck B, Dreher R, et al. Production of clenbuterol, diethylstilbestrol and trenbolone mass standards in lyophilised bovine urine [J]. Anal. Chim. Acta, 2003, 483(1-3):401-412.
Zhang S H, Wu K B, Hu S S. Voltammetric determination of diethylstilbestrol at carbon paste electrode using cetylpyridine bromide as medium [J]. Talanta, 2002, 58(4):747-754.
Biryol I, Salci B, Erdik E. Voltammetric investigation of diethylstilbestrol [J]. Journal of Pharmaceutical and Biomedical Analysis, 2003, 32(6):1227-1256.
Wang S, Huang W, Fang G, et al. On-line coupling of solid-phase extraction to high-performance liquid chromatography for determination of estrogens in environment [J]. Anal. Chim. Acta, 2008, 606(2):194-201.
Liu M H, Qiu B, Jin X, et al. Determination of estrogens in wastewater using three-phase hollow fiber-mediated liquid-phase microextraction followed by HPLC [J]. J. Sep. Sci., 2008, 31(4):622-628.
Seo J, Kim H Y, Chung B C, et al. Simultaneous determination of anabolic steroids and synthetic hormones in meat by freezing-lipid filtration, solid-phase extraction and gas chromatography-mass spectrometry [J]. Chromatogr. A, 2005, 1067(1-2):303-309.
Yang L H, Luan T G, Lan C Y. Solid-phase microextraction with on-fiber silylation for simultaneous determinations of endocrine disrupting chemicals and steroid hormones by gas chromatography-mass spectrometry [J]. J. Chromatogr. A, 2006, 1104(1-2):23-32.
Wang W J, Ling Y, Xu T, et al. Development of an indirect competitive ELISA based on polyclonal antibody for the detection of diethylstilbestrol in water samples [J]. Chin. J. Chem., 2007, 25(8):1145-1150.
Wang W J, Li J, Zhao J X, et al. Development of monoclonal antibody-based enzyme-linked immunosorbent assay to the estrogen diethylstilbestrol [J]. Chin. J. Chem., 2006, 24(12):1758-1765.
Wang S H, Zhuang H S, Yao X J, et al. Flow injection chemiluminescence method for the determination of diethylstilbestrol with N-bromosuccinimide luminol system [J]. Chinese Journal of Analysis Laboratory (分析试验室), 2006, 25(8):10-12 (in Chinese).
LI Z, Wang Y, Zhang G, Xu W, et al. Chemiluminescence resonance energy transfer in the lumino-CdTe quantum dots conjugates [J]. J. Lumin., 2010, 130(6):995-999.
Huang H, Tan Y, Shi J, et al. DNA aptasensor for the detection of ATP based on quantum dots electrochemiluminescence [J]. Nanoscale, 2010, 2(4):606-612.
Andrade J J, Brasil Jr A G, Farias P M A, et al. Synthesis and characterization of blue emitting ZnSe quantum dots [J]. Microelectr. J., 2009, 40(3):641-643.
Zeng H J, Yang R, Wang Q W, et al. Determination of melamine by flow injection analysis based on chemiluminescence system [J]. Food Chemistry, 2011, 127(2):842-846.