AODENG Gaowa, AN Na, LING Xiao, MIAO Shu. Spectrophotometric Determination of Piperlonguminine Based on The Charge Transfer Reaction Between Piperlonguminine and <em>o</em>-Nitrophenyl Fluorone[J]. Chinese Journal of Luminescence, 2012,(5): 558-561
AODENG Gaowa, AN Na, LING Xiao, MIAO Shu. Spectrophotometric Determination of Piperlonguminine Based on The Charge Transfer Reaction Between Piperlonguminine and <em>o</em>-Nitrophenyl Fluorone[J]. Chinese Journal of Luminescence, 2012,(5): 558-561 DOI: 10.3788/fgxb20123305.0558.
Spectrophotometric Determination of Piperlonguminine Based on The Charge Transfer Reaction Between Piperlonguminine and o-Nitrophenyl Fluorone
A rapid and convenient spectrophotometric method for the determination of piperlonguminine was established in the present work. The method utilized charge transfer reaction between piperlonguminine and
o
-nitrophenyl fluorone in pH 7.00 buffer solution. The maximum absorption wavelength of the charge transfer complex was at 515 nm and the apparent molar absorptivity was 6.57110
4
Lmol
-1
cm
-1
with a 1 ∶1 stoichiometry. Beers law was obeyed in the range of 0.054 6~10.92 g/mL of piperlonguminine with the detection limit of 0.015 3 g/mL. The reaction mechanism was discussed preliminarily. The proposed method was applied to the biological and urine samples spiked with standard piperlonguminine solution. The recovery of the samples was within the range of 99.8%~100.9% and relative standard deviation (RSD) was 0.90%.
关键词
Keywords
references
Ma Chunjie, Borjihan Gerelu, Hurilebagen, et al. Antiatherogenic effect of piperlonguminine on experimental atherosclerosis in rabbits [J]. China Journal of Chinese Materia Medica (中国中药杂志), 2008, 33(4):436-440 (in Chinese).[2] Du Licheng, He Ping, Li Xiaohong, et al. Determination of neodymium using fluorimetric liquid method [J]. Chin. J. Lumin.(发光学报), 2010, 31(6):936-941 (in Chinese).[3] Ling Xiao, Borjihan Gerelu, Zhou Haijun, et al. Fluorescence characteristics and analytical application of Mn(Ⅱ)-pipe-rine-cetyltrimethylammonium bromide ternary system [J]. Spectroscopy and Spectral Analysis (光谱学与光谱分析), 2009, 1(3):188-190 (in Chinese).[4] Xue Yonglin, Gao Ling, Pen Shouxin. Determination based on chemometricspectral geminated vitamin B1,B2 and B6 [J]. Chin. J. Lumin.(发光学报), 2011, 32(10):1081-1087 (in Chinese).[5] Pandeeswaran M, Elango K P. Spectroscopic studies on the interact ion of cimetidine drug with biologically significant and acceptors [J]. Spectrochimica Acta Part A, 2010, 75:1462-1469.