YUE Shu-mei, ZHANG Li, LI Bin, LIU Chang, LI Wen-lian. Oxygen Sensing Properties Based on Organically Modified Sol-gel Doped with Ru-Dppz[J]. Chinese Journal of Luminescence, 2007,28(3): 345-348
YUE Shu-mei, ZHANG Li, LI Bin, LIU Chang, LI Wen-lian. Oxygen Sensing Properties Based on Organically Modified Sol-gel Doped with Ru-Dppz[J]. Chinese Journal of Luminescence, 2007,28(3): 345-348DOI:
Oxygen Sensing Properties Based on Organically Modified Sol-gel Doped with Ru-Dppz
An oxygen sensing material using tetramethoxysilane (TEOS) and n-octyltriethoxysilane (Octyl-triEOS) as precursors and doped with bis(2
2-bipyridine)(dipyrido[3
3-a 2
3-c]phenazine-N
4
N
5
)ruthenium(Ⅱ) (Ru-Dppz) was prepared by the sol-gel method. The fluorescent behaviors of the complex in ethanol and xerogel were investigated. As a result
the emission band of the composite material attributed to the transition from the metal-to-ligand charge transfer (MLCT) shows blue shift compared with that in ethanol. The lifetime of the complex in xerogel was increased compared with that of the pure solid complex. The sensing material with Ru-Dppz as indicator demonstrated good Stern-Volmer plot
high sensitivity
fast response time and long-term stability. The sensitivity was improved using an organically modified silicate (ormosil) as a matrix.
关键词
Keywords
references
Tang Y,Tehan E C,Tao Z,et al.Sol-gel-derived sensor materials that yield linear calibration plots,high sensitivity,and long-term stability[J].Anal.Chem.,2003,75(10):2407-2413.
Carraway E R,Demas J N,DeGraff B A,et al.Photophysics and photochemistry of oxygen sensors based on luminescent transition-mental complexes[J].Anal.Chem.,1991,63(4):337-342.
Bukowski R M,Ciriminna R,Bright F V,et al.High-performance quenchometric oxygen sensors based on fluorinated xerogels doped with[Ru(dpp)3]2+[J].Anal.Chem.,2005,77(8):2670-2672.
Zhang P,Guo J H,Wang Y,et al.Incorporation of luminescent tris(bipyridine)ruthenium(Ⅱ) complex in mesoporous silica spheres and their spectroscopic and oxygen-sensing properties[J].Mater.Lett.,2002,53(6):400-405.
Innocenzi P,Kozuka H,Yoko T,et al.Fluorescence properties of the Ru(bpy)32+ complex incorporated in sol-gel-derived silica coating films[J].J.Phys.Chem.B,1997,101(13):2285-2291.
Murtagh M T,Shahriari M R,Krihak M.A study of the effects of organic modification and processing technique on the luminescence quenching behavior of sol-gel oxygen sensors based on a Ru(Ⅱ) complex[J].Chem.Mater.,1998,10(12):3862-3869.
Fuller Z J,Bare W D,Kneas K A,et al.Photostability of luminescent ruthenium(Ⅱ) complexes in polymers and in solution[J].Anal.Chem.,2003,75(11):2670-2677.
Amouyal E,Homis A,Chambron J C,et al.Synthesis and study of a mixed-ligand ruthenium(Ⅱ) complex in its ground and excited states:bis(2,2-bipyridine)(dipyrido[3,3-a:2,3-c] phenazine-N4N5) ruthenium(Ⅱ)[J].J.Chem.Soc.,Dalton Trans.,1990,(6):1841-1845.
Chen X,Li Z,Jiang Y Q,et al.Oxygen sensing film based on organically modified sol-gel with ruthenium complexes and their fluorescent spectra studies[J].Spectroscopy and Spectral Analysis(光谱学与光谱分析),2002,22(5):796-799 (in Chinese).
Marco G D,Lanza M,Campagna S,et al.Luminescent RuⅡ-polypyridine complexes in poly-2-hydroxyethylmethacrylate matrices as oxygen sensors[J].Adv.Mater.,1995,7(5):468-471.