STUDIES ON TIME-RESOLVED FLUORIMETRY OF RARE EARTH CHELATES(Ⅱ)——THE FLUORESCENT DECAY PROPERTIES AND LASER-INDUCED TIME-RESOLVED FLUORIMETRY OF Eu,Sm-DBM-TOPO SYSTEM
|更新时间:2020-08-11
|
STUDIES ON TIME-RESOLVED FLUORIMETRY OF RARE EARTH CHELATES(Ⅱ)——THE FLUORESCENT DECAY PROPERTIES AND LASER-INDUCED TIME-RESOLVED FLUORIMETRY OF Eu,Sm-DBM-TOPO SYSTEM
Chinese Journal of LuminescenceVol. 11, Issue 4, Pages: 300-305(1990)
Hu Jiming, Chen Guanquan, Zeng Yune. STUDIES ON TIME-RESOLVED FLUORIMETRY OF RARE EARTH CHELATES(Ⅱ)——THE FLUORESCENT DECAY PROPERTIES AND LASER-INDUCED TIME-RESOLVED FLUORIMETRY OF Eu,Sm-DBM-TOPO SYSTEM[J]. Chinese Journal of Luminescence, 1990,11(4): 300-305
Hu Jiming, Chen Guanquan, Zeng Yune. STUDIES ON TIME-RESOLVED FLUORIMETRY OF RARE EARTH CHELATES(Ⅱ)——THE FLUORESCENT DECAY PROPERTIES AND LASER-INDUCED TIME-RESOLVED FLUORIMETRY OF Eu,Sm-DBM-TOPO SYSTEM[J]. Chinese Journal of Luminescence, 1990,11(4): 300-305DOI:
STUDIES ON TIME-RESOLVED FLUORIMETRY OF RARE EARTH CHELATES(Ⅱ)——THE FLUORESCENT DECAY PROPERTIES AND LASER-INDUCED TIME-RESOLVED FLUORIMETRY OF Eu,Sm-DBM-TOPO SYSTEM
a multifunctional laser-induced time-resolved fluorimeter is described. Basic components of the device are: anactive Q-switched Nd:YAG pumped dye laser(YG581/TDL50) as the excitation light source
a gated vidicon optical multichannel analyzer(WPl/WP2) as the fluorescence detecting equipment
and a electric trigger which made by our laboratory as the external trigger source. The applied software and interface between IBM PC/XT computer and the fluorimeter are designed for data acquisition and data processing of fluorescent spectra.Using the output of frequency tripling of Nd:YAG laser(355nm)
the DBM(dibenzoylmethane) produces very much weaker luminescence in 430-510nm
whereas TOPO(tri-n-octylphosphine oxide) has much stronger luminescence in 365-430nm. The data of luminescence lifetime demonstrate that the luminescence of DBM and of TOPO are phosphorescence and fluorescence
respectively. However
the fluorescence emission of TOPO decreased remarkably in the presence of DBM. The sharp line emission of RE-DBM-TOPO systems is observed
Eu-DBM-TOPO and Sm-DBM-TOPO show very intense emission
whereas Tb-DBM-TOPO shows very weak emission in high concentration. The fluorescence emissions of RE-DBM are very much weaker than those of RE-DBM-TOPO
but the characteristic emissions aren't observed in RE-TOPO. The fluorescence lifetimes of Eu-DBM
Eu-DBM-TOPO
Sm-DBM and Sm-DBM-TOPO are measured to be 100
500
32 and 45us at room temperature using this device
respectively. The fluorescence lifetmes are similar for the different characteristic emission of each chelate. The fluorescence decay curves show exponential decay process for fluorescenc emission of RE-DBM and nonexponential decay process for fluorescence emission of RE-DBM-TOPO.